Technical Data
60-Foot Stadium Light Tower Specifications
Technical specifications for our portable stadium light towers, grouped for procurement and site planning teams.
Technical Views
Technical Drawings.
Six views of the tower in its travel position: 16 LED floodlights, 60-foot telescoping tower, integrated diesel generator, tandem-axle trailer and outriggers.
- 16 LED floodlights
- Tandem-axle trailer
- Outriggers for stabilization
Technical ViewsRental unit






Lighting
| Fixtures | 16 independently adjustable LED floodlights |
|---|---|
| Total output | 1,250,000 lumens |
| Output per fixture | 78,125 lumens |
| Power per fixture | 500 W |
| Total lighting load | 8,000 W |
| Lighting voltage | 240 V |
| Visibility | Greater than 1,500 ft |
| Fixture aiming | Individually aimed without tools |
Tower & Positioning
| Tower | 60-foot telescoping tower |
|---|---|
| Lift system | Combined hydraulic-cable lift system |
| Rotation | 340° tower rotation |
| Operating height | Lights operate at any tower height |
| Stabilization | Stabilizing outriggers; no guy-lines required |
| Beacon | Operational flashing beacon at top of tower |
| Wind-load rating | 80 mph sustained winds; 120 mph gusts |
Integrated Diesel Generator
| Generator | Integrated 12 kW diesel generator |
|---|---|
| Standby rating | 12 kW / 16.1 hp |
| Prime rating | 10.8 kW / 14.5 hp |
| Engine | Industrial 3-cylinder, 1.5 L, indirect-injection, water-cooled diesel |
| Alternator | Industrial-grade, 1,800 rpm, 4-pole, single bearing; brushless excitation with permanent-magnet boost; Class H insulation |
| Voltage regulation | Digital automatic voltage regulator; less than 5% total harmonic distortion |
| Output voltage / frequency | 120/240 V, 60 Hz |
| Emissions | U.S. EPA Tier 4 Final |
| Fuel tank | 49 gal (186 L) |
| Fuel consumption | 0.8 gal/hour (3 L/hour) |
| Continuous runtime | 61 hours |
| External fueling | JIC10 fuel supply/return connections; internal/external fuel selector valve |
| Charging and battery | 40 A, 12 VDC charge alternator; 12 VDC, 650 CCA cranking battery; battery disconnect switch |
Controller & Enclosure
| System controller | Digital; backlit, heated LCD for all-weather operation |
|---|---|
| Controller operating temperature | -40°F to 185°F (-40°C to 85°C) |
| Monitoring | Engine speed, fuel level, battery voltage, kW/kVA output, line currents, voltages and frequency |
| Alarms and shutdowns | Overload; overcurrent and short circuit; under/over voltage and frequency; fuel level; overspeed; battery and charge-alternator failure |
| Programming | Configurable event log; programmable PLC |
| Enclosure | 12-gauge galvanized steel; UV-resistant polyester powder coat |
| Sound attenuation | Inlet baffles and fire-resistant acoustic foam |
| Security | Lockable control-box door with viewing window; key- or pad-lockable enclosure, including fuel fill |
| Service access | Fuel, oil and coolant drains plumbed to exterior; vibration-isolated engine/generator |
| Safety | Emergency-stop switch; main circuit breaker; battery disconnect |
Transport & Setup
| Transport configuration | Tandem-axle trailer; tower lowered in travel position |
|---|---|
| Stabilization | Outriggers; no guy-lines required |
| Delivery | Delivered to your site as part of the rental |
Environmental & Compliance
| Wind-load rating | 80 mph sustained; 120 mph gusts |
|---|---|
| Emissions | U.S. EPA Tier 4 Final |
| Controller operating temperature | -40°F to 185°F (controller display) |
Specifications are subject to change without notice.
Need specifications for a bid or site plan?
Request technical specifications and pricing for your project.